MDR-3002-S加氢站用氢气泄漏检测仪

产品名称/Product Name:加氢站用氢气泄漏检测仪

测量范围/Measuring range:0~40000ppm

检测原理/Detection principle:量子电导

响应时间/Response time:≤2s

恢复时间/Recovery time:≤3s

输出信号/Output signal:RS485信号输出

防护等级/IP code:IP67

工作环境/Operating tempreture:-20℃~60℃
应用场景/Application scenario:主要应用于加氢站,也用于氢能源发电站、化工厂、冶金厂等工业领域。


产品质保

品质保证

两年质保,终身维护

合作模式

合作模式

经销、代理、OEM/ODM

售后服务

售前售后

12小时内快速回应

         加氢站用氢气泄漏检测仪是一款基于团簇阵列中的量子隧穿效应的固定式氢气传感器,响应氢气浓度变化的时间小于两秒。本产品采用自然扩散的检测方式,采用新型技术生产,具有响应速度快,恢复时间短,抗干扰能力强,功耗低等特点,在性能上获得了突破性的提高。本产品主要应用于加氢站环境下的氢气泄漏检测,在保障加氢站安全、提高运营效率以及促进可持续发展等方面发挥着重要作用。
      The Hydrogen leak detector for hydrogen refueling stations is a stationary hydrogen sensor based on quantum tunneling in cluster arrays and responds to changes in hydrogen concentration in less than two seconds. This product adopts the natural diffusion detection method, adopts the new technology production, has the characteristics of fast response speed, short recovery time, strong anti-interference ability, low power consumption, and has obtained a breakthrough in performance. This product is mainly used in hydrogen leakage detection in the environment of hydrogen refueling stations, and plays an important role in ensuring the safety of hydrogen refueling stations, improving operational efficiency and promoting sustainable development.
应用场景/Application scenario

加氢站用氢气泄漏检测仪


安装方式/Installation mode

固定式氢气传感器安装方式

安装位置/Installation position

        探测器安装在被检测气体易泄漏场所,安装位置根据被检测气体相对于空气比重大小决定。检测比空气重的气体,探测器应靠近泄漏点,安装高度应距地面0.3~0.6m,且传感器部位向下。检测比空气轻的气体时,探测器应靠近泄漏点安装,高度距离天花板0.3-0.6m处,且传感器部位向下。
        The detector is installed in a place where the detected gas is easy to leak, and the installation position is determined by the specific gravity of the detected gas relative to the air. For detecting gases heavier than air, the detector should be close to the leak point, installed 0.3 to 0.6m above the ground, and the sensor position should be downward. When detecting gases lighter than air, the detector should be installed close to the leak point, 0.3-0.6m from the ceiling, and the sensor position should be downward.


测量范围/Measuring range:0~40000ppm

检测原理/Detection principle:量子电导

响应时间/Response time:≤2s(室温)

恢复时间/Recovery time:≤3s(室温)

输出信号/Output signal:RS485信号输出

工作环境/Operating tempreture:-20~60

相对湿度/Relative humidity:≤95%RH

防护等级/IP code:IP67

安装方式/Fix method:壁挂式

检测方式/Detection mode:扩散式

报警输出/Alarm:声光报警

连接电缆/Connection cable:四芯缆

工作电压/Operating voltage:DC24V(默认/Default)12V(可选/Optional)

防爆类型/Explosion proof:探头变送器及传感器均为隔爆型


固定式氢气传感器尺寸图

相关产品
相关问答咨询 更多
基于量子电导原理的氢气传感器的优势及应用有哪些?

Q:基于量子电导原理的氢气传感器的优势及应用有哪些?

        在科技飞速发展的今天,我们越来越依赖各种传感···

2024-01-30
氢气传感器在氢能源汽车中的应用,你了解多少?

Q:氢气传感器在氢能源汽车中的应用,你了解多少?

        随着环保意识的日益增强和···

2023-08-24
汽车上的传感器有哪些和作用?

Q:汽车上的传感器有哪些和作用?

       汽车传感器的作用是检测与点火提前角有关的发动机工况信息,并将信息输···

2023-03-08
相关技术文章 更多
车载供氢系统泄漏检测:关键模块解析与安全保障措施

车载供氢系统泄漏检测:关键模块解析与安全保障措施

        车载供氢系统是氢燃料电池电动汽车(FCEV)···

2024-04-24
倾角传感器:原理、特性及多元化应用领域详解

倾角传感器:原理、特性及多元化应用领域详解

        倾角传感器是一种专门设计···

2024-04-23
刮板机断链保护器安装指南:从准备到验收的全流程详解

刮板机断链保护器安装指南:从准备到验收的全流程详解

        刮板机断链保护器的安装是···

2024-04-19
在线客服

业务咨询

技术咨询

售后服务

PC端自动化二维码
135-1581-0281 (即时通话) 459879587 (在线询价) 135-1581-0281 (长按复制)
扫码加微信